Construction and response of a highly granular scintillator-based electromagnetic calorimeter
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Here, a highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 depth and transverse dimensions was constructed, consisting of 2160 individually read out scintillator strips. This prototype was tested using electrons of 2–32 at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be , where the uncertainties correspond to statistical and systematic sources, respectively.
- Research Organization:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Organization:
- USDOE
- Contributing Organization:
- The CALICE Collaboration
- Grant/Contract Number:
- AC02-06CH11357
- OSTI ID:
- 1477880
- Alternate ID(s):
- OSTI ID: 23120173
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 887; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Silicon photomultipliers for high energy physics detectors
|
journal | October 2011 |
Silicon photomultiplier and its possible applications
|
journal | May 2003 |
Geant4—a simulation toolkit
|
journal | July 2003 |
Limited Geiger-mode microcell silicon photodiode: new results
|
journal | March 2000 |
A tungsten/scintillating fiber electromagnetic calorimeter prototype for a high-rate muon experiment
|
journal | April 2009 |
Particle flow calorimetry and the PandoraPFA algorithm
|
journal | November 2009 |
Uniformity studies of scintillator tiles directly coupled to SiPMs for imaging calorimetry
|
journal | August 2010 |
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
|
journal | November 2014 |
A novel strip energy splitting algorithm for the fine granular readout of a scintillator strip electromagnetic calorimeter
|
journal | July 2015 |
Beam test of a small MICROMEGAS DHCAL prototype
|
journal | January 2010 |
Silicon photomultipliers for high energy physics detectors
|
journal | October 2011 |
5×5 mm2 granular electromagnetic calorimeter using 45 × 5 mm2 scintillator strips and SiPMs
|
conference | November 2014 |
Similar Records
Measurement of the CP-violating phase ϕs in the
channel in proton-proton collisions at
Journal Article
·
Tue Mar 02 19:00:00 EST 2021
· Phys.Lett.B
·
OSTI ID:1647064