Here PET, in conjunction with CT,1 has been an important tool in the management of oncology patients, accounting for 86% of PET scans by 2016,2 PET with attenuation and motion correction has significant potential for future cardiac applications, especially with the ability of PET to perform dynamic imaging to measure myocardial perfusion—myocardial blood flow (MBF) and coronary flow reserve (CFR), integrity of neural transmitters of the autonomic nervous system, and connecting cardiac efficiency with metabolism of myocardial substrates.

Research Organization:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
Grant/Contract Number:
AC02-05CH11231
OSTI ID:
1477265
Journal Information:
Journal of Nuclear Cardiology, Vol. 26, Issue 4; ISSN 1071-3581
Publisher:
Springer NatureCopyright Statement
Country of Publication:
United States
Language:
English

References (33)

Benefit of Time-of-Flight in PET: Experimental and Clinical Results journal February 2008
Improved Intrinsic Motion Detection Using Time-of-Flight PET journal October 2015
Myocardial flow reserve (MFR) with positron emission tomography (PET)/computed tomography (CT): clinical impact in diagnosis and prognosis journal April 2017
Application of Silicon Photomultipliers to Positron Emission Tomography journal February 2011
Preclinical and Translational PET/MR Imaging journal May 2014
Recent Advances and Future Progress in PET Instrumentation journal January 2016
Studies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System journal April 2017
Imaging of myocardial fatty acid oxidation journal October 2016
Hypertensive left ventricular hypertrophy is associated with abnormal myocardial fatty acid metabolism and myocardial efficiency journal June 2006
Free Fatty Acid Depletion Acutely Decreases Cardiac Work and Efficiency in Cardiomyopathic Heart Failure journal November 2006
System models for PET statistical iterative reconstruction: A review journal March 2016
Recent Advances and Clinical Applications of PET Cardiac Autonomic Nervous System Imaging journal March 2017
Selective improvement in Seattle Heart Failure Model risk stratification using iodine-123 meta-iodobenzylguanidine imaging journal September 2012
Approaches to Reducing Radiation Dose from Radionuclide Myocardial Perfusion Imaging journal March 2015
Pushing the Limits in Time-of-Flight PET Imaging journal November 2017
Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET journal February 2011
Relationship Between Carbohydrate and Lipid Metabolism and the Energy Balance of Heart Muscle journal March 1974
Palmitate attenuates myocardial contractility through augmentation of repolarizing Kv currents journal February 2010
Time-of-flight PET data determine the attenuation sinogram up to a constant journal January 2012
Characterization of 3-Dimensional PET Systems for Accurate Quantification of Myocardial Blood Flow journal August 2016
Journey in Evolution of Nuclear Cardiology journal December 2012
Improving Depth, Energy and Timing Estimation in PET Detectors with Deconvolution and Maximum Likelihood Pulse Shape Discrimination journal November 2016
Quantitative accuracy of PET/CT for image-based kinetic analysis: Quantitative accuracy of PET/CT journal June 2008
Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction journal December 2017
Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction: Ultra-low dose PET CT attenuation correction journal January 2015
Longitudinal Evaluation of Sympathetic Nervous System and Perfusion in Normal and Spontaneously Hypertensive Rat Hearts with Dynamic Single-Photon Emission Computed Tomography journal July 2015
Image Quality and Diagnostic Performance of a Digital PET Prototype in Patients with Oncologic Diseases: Initial Experience and Comparison with Analog PET journal July 2015
Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions journal June 2014
Retention Kinetics of the 18F-Labeled Sympathetic Nerve PET Tracer LMI1195: Comparison with 11C-Hydroxyephedrine and 123I-MIBG journal July 2015
Longitudinal Evaluation of Left Ventricular Substrate Metabolism, Perfusion, and Dysfunction in the Spontaneously Hypertensive Rat Model of Hypertrophy Using Small-Animal PET/CT Imaging journal October 2013
Iterative reconstruction techniques in emission computed tomography journal July 2006
Using convolutional neural networks to estimate time-of-flight from PET detector waveforms journal January 2018
Time-of-flight PET journal July 1998

Figures / Tables (2)