This summer internship here at Pantex pertained to how one may approach equipment and apply Reliability Centered Maintenance. Reliability Centered Maintenance (RCM), is a strategy for maintenance first used in the 1960’s. Within this strategy there are three methods of maintenance, preventative, run-till-failure, and condition based and these will be what a part may be categorized into. When approaching equipment/parts to decide which category they fall into they must go under a five procedures, Criticality, Fault Tree Analysis, Task Analysis, Effectiveness, and Cost. The pilot project was to test the maintenance strategies on the preventative maintenance [PM’s] work orders used on Air Handling Units (AHU) and Dehumidifying Units (DHU) here at the Pantex Plant. This was accomplished by making recommendations on the preventative maintenance work orders.
Research Organization:
Pantex Plant (PTX), Amarillo, TX (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
NA0001942
OSTI ID:
1477016
Report Number(s):
IROS5682
Country of Publication:
United States
Language:
English

Similar Records

Reliability centered maintenance (RCM) for substations project overview
Technical Report · Thu Aug 01 00:00:00 EDT 1996 · OSTI ID:430392

RCM and component evaluation logic
Conference · Mon Dec 31 23:00:00 EST 1990 · Proceedings of the American Power Conference; (United States) · OSTI ID:5106544

A comprehensive approach to RCM-based preventive maintenance program development
Conference · Thu Dec 31 23:00:00 EST 1987 · Transactions of the American Nuclear Society; (USA) · OSTI ID:5431960

Related Subjects