Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

RADIATION DOSIMETRY AT THE BNL HIGH FLUX BEAM REACTOR AND MEDICAL RESEARCH REACTOR.

Conference ·
OSTI ID:14645
 [1]
  1. BROOKHAVEN NATIONAL LABORATORY
RADIATION DOSIMETRY MEASUREMENTS HAVE BEEN PERFORMED OVER A PERIOD OF MANY YEARS AT THE HIGH FLUX BEAM REACTOR (HFBR) AND THE MEDICAL RESEARCH REACTOR (BMRR) AT BROOKHAVEN NATIONAL LABORATORY TO PROVIDE INFORMATION ON THE ENERGY DISTRIBUTION OF THE NEUTRON FLUX, NEUTRON DOSE RATES, GAMMA-RAY FLUXES AND GAMMA-RAY DOSE RATES. THE MCNP PARTICLE TRANSPORT CODE PROVIDED MONTE CARLO RESULTS TO COMPARE WITH VARIOUS DOSIMETRY MEASUREMENTS PERFORMED AT THE EXPERIMENTAL PORTS, AT THE TREATMENT ROOMS AND IN THE THIMBLES AT BOTH HFBR AND BMRR.
Research Organization:
Brookhaven National Lab., Upton, NY (US)
Sponsoring Organization:
DOE/SC (US)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
14645
Report Number(s):
BNL--66807; KC02, KP14; KC02, KP14
Country of Publication:
United States
Language:
English

Similar Records

Radiation dosimetry at the BNL reactor facilities
Journal Article · Thu Jul 01 00:00:00 EDT 1999 · Transactions of the American Nuclear Society · OSTI ID:20005835

Radiation dosimetry at the BNL Medical Research Reactor
Conference · Sat Oct 31 23:00:00 EST 1998 · OSTI ID:663503

Radiation dosimetry for NCT facilities at the Brookhaven Medical Research Reactor
Conference · Wed Dec 30 23:00:00 EST 1998 · OSTI ID:325742