Effects & control of pulsations in gas measurement
Conference
·
OSTI ID:146259
- El Paso Natural Gas Co., TX (United States)
The effects of pulsation on orifice recorders is detrimental to the accurate measurement of natural gas. However, it can be reduced with the installation of pulsation filter bottles between the compressor and the meter station facility. Acoustically, the pulsation can be reduced to a minimal Square Root Error (SRE) reducing the overstatement of natural gas which, in turn, saves a considerable amount of money over time. To obtain reliable measurements, it is necessary to suppress any apparent pulsation.
- OSTI ID:
- 146259
- Report Number(s):
- CONF-950553--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cures given for reciprocating compressor pulsation
Pulsation control improves gas measurement
Reduce residual pulsation in reciprocating compressors
Journal Article
·
Sun Apr 06 23:00:00 EST 1980
· Oil Gas J.; (United States)
·
OSTI ID:5253931
Pulsation control improves gas measurement
Journal Article
·
Mon Sep 08 00:00:00 EDT 1980
· Oil Gas J.; (United States)
·
OSTI ID:5151617
Reduce residual pulsation in reciprocating compressors
Journal Article
·
Sat Jul 01 00:00:00 EDT 1995
· Hydrocarbon Processing
·
OSTI ID:80159