This report presents the results of an inspection around fastener holes in simulated lap splice specimens using a Nortec-30 Eddyscan inspection system. The inspector performing the tests had no prior knowledge of the extent or location of cracks in the specimens examined. The results of the inspection are presented in terms of various probability of detection curve models and are compared to various other eddy current inspections performed on the same set of test specimens. Results indicate that the system is capable, with high confidence, of detecting 60 to 70 mil cracks from under countersink fasteners.

Research Organization:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Organization:
Federal Aviation Administration, Washington, DC (United States)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
142537
Report Number(s):
SAND--94-0128; ON: DE94008831; CNN: Contract DTFA-03-91-A-0018
Country of Publication:
United States
Language:
English

Similar Records

Effect of conductivity between fasteners and aluminum skin on eddy current specimens
Conference · Mon Mar 31 23:00:00 EST 1997 · OSTI ID:460783

Multifrequency Eddy Current Inspection of Corrosion in Clad Aluminum Riveted Lap Joints and Its Effect on Fatigue Life
Journal Article · Wed Mar 21 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:21054941

Protocol assessment of a field reliability experiment at the NDI Validation Center
Journal Article · Sat Jul 01 00:00:00 EDT 1995 · Materials Evaluation · OSTI ID:99219