Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

2017 Guralp Affinity Digitizer Evaluation.

Technical Report ·
DOI:https://doi.org/10.2172/1425328· OSTI ID:1425328
 [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

Sandia National Laboratories has tested and evaluated two Guralp Affinity digitizers. The Affinity digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
CTBTO; USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1425328
Report Number(s):
SAND--2018-2136; 661001
Country of Publication:
United States
Language:
English