Resonant cavity Vircator driven by a thermionic cathode electron beam gun

Journal Article · · IEEE Transactions on Plasma Science
DOI:https://doi.org/10.1109/27.256794· OSTI ID:142415
 [1]
  1. Texas Instrument, Dallas, TX (United States)
A resonant cavity Vircator (virtual cathode oscillator) driven by an electron beam emitted from a broad area thermionic cathode has been tested at Textron Defense Systems. Narrow bandwidth (1.0 MHz at the {minus}3 dB level) excitation of the TM{sub 0.23} mode of a cylindrical resonant cavity was observed at a frequency of 986 MHz with a pulse length of 1.2 {mu}s. The single cavity mode excitation is attributed to the constant voltage and current electron beam emitted form the thermionic cathode.