Title: Finalized configuration of magnetic shielding for LEReC cooling section

Abstract

In the LEReC Cooling Section (CS) the RHIC ions are traveling together with and getting cooled by the LEReC electrons. The required cooling rate sets the limit of 150 urad on tolerable angles of the electrons in the CS. One of the components of overall electron angle is the angle of the e-beam trajectory with respect to the ion beam trajectory. We set the limit for electron trajectory angle to 100 urad. It is critical for preserving small trajectory angle to keep the transverse magnetic field inside the CS drifts within +/- 2.3 mG. The drifts in the CS must be shielded from the ambient magnetic fields of the RHIC tunnel, which can be as high as 0.5 G, to minimize the transverse field inside the CS vacuum chamber. In this paper we present the final design of the magnetic shielding of the LEReC CS and discuss the results of tests dedicated to studies of the shielding effectiveness.

Authors:
 [1];  [1];  [1];  [1];  [1];  [1];  [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)
Publication Date:
Research Org.:
Brookhaven National Laboratory (BNL), Upton, NY (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Nuclear Physics (NP) (SC-26)
OSTI Identifier:
1412760
Report Number(s):
BNL-114736-2017-IR
DOE Contract Number:  
SC0012704
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS

Citation Formats

Seletskiy, S., De Monte, V., Di Lieto, A., Fedotov, A., Mahler, G., McIntyre, G., Tuozzolo, J., and Weiss, D. Finalized configuration of magnetic shielding for LEReC cooling section. United States: N. p., 2017. Web. doi:10.2172/1412760.
Seletskiy, S., De Monte, V., Di Lieto, A., Fedotov, A., Mahler, G., McIntyre, G., Tuozzolo, J., & Weiss, D. Finalized configuration of magnetic shielding for LEReC cooling section. United States. doi:10.2172/1412760.
Seletskiy, S., De Monte, V., Di Lieto, A., Fedotov, A., Mahler, G., McIntyre, G., Tuozzolo, J., and Weiss, D. Mon . "Finalized configuration of magnetic shielding for LEReC cooling section". United States. doi:10.2172/1412760. https://www.osti.gov/servlets/purl/1412760.
@article{osti_1412760,
title = {Finalized configuration of magnetic shielding for LEReC cooling section},
author = {Seletskiy, S. and De Monte, V. and Di Lieto, A. and Fedotov, A. and Mahler, G. and McIntyre, G. and Tuozzolo, J. and Weiss, D.},
abstractNote = {In the LEReC Cooling Section (CS) the RHIC ions are traveling together with and getting cooled by the LEReC electrons. The required cooling rate sets the limit of 150 urad on tolerable angles of the electrons in the CS. One of the components of overall electron angle is the angle of the e-beam trajectory with respect to the ion beam trajectory. We set the limit for electron trajectory angle to 100 urad. It is critical for preserving small trajectory angle to keep the transverse magnetic field inside the CS drifts within +/- 2.3 mG. The drifts in the CS must be shielded from the ambient magnetic fields of the RHIC tunnel, which can be as high as 0.5 G, to minimize the transverse field inside the CS vacuum chamber. In this paper we present the final design of the magnetic shielding of the LEReC CS and discuss the results of tests dedicated to studies of the shielding effectiveness.},
doi = {10.2172/1412760},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Nov 20 00:00:00 EST 2017},
month = {Mon Nov 20 00:00:00 EST 2017}
}

Technical Report:

Save / Share: