NeutronSTARS: A segmented neutron and charged particle detector for low-energy reaction studies

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [2];  [3];  [3];  [3];  [3];  [4];  [3]
  1. Univ. of California, Berkeley, CA (United States); Nuclear Science and Security Consortium
  2. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
  3. Univ. of California, Berkeley, CA (United States)
  4. Texas A & M Univ., College Station, TX (United States)

NeutronSTARS (Neutron-Silicon Telescope Array for Reaction Studies) consists of 2.2-tons of gadolinium-doped liquid scintillator for neutron detection and large area silicon detectors for charged particle identification. This detector array is intended for low-energy-nuclear-reaction measurements that result in the emission of neutrons such as (n, xn) and fission. This paper describes the NeutronSTARS experimental setup, calibration, and the array’s response to neutral and charged particles.

Research Organization:
Nuclear Science and Security Consortium
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation (NA-20)
Grant/Contract Number:
NA0003180
OSTI ID:
1407973
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Issue: C Vol. 872; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (15)

Monte Carlo studies of scintillator efficiencies and scatter corrections for (n,2n) cross section measurements journal March 1968
A flexible 4π neutron detector for in-beam studies: the Texas A&M neutron ball
  • Schmitt, R. P.; Cooke, L.; Derrig, G.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 354, Issue 2-3 https://doi.org/10.1016/0168-9002(94)01029-3
journal January 1995
Tagging fast neutrons from an 241Am/9Be source journal April 2015
Tagging fast neutrons from a 252 Cf fission-fragment source journal October 2017
MCNP-PoliMi: a Monte-Carlo code for correlation measurements
  • Pozzi, Sara A.; Padovani, Enrico; Marseguerra, Marzio
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 513, Issue 3 https://doi.org/10.1016/j.nima.2003.06.012
journal November 2003
NIMROD–ISiS, a versatile tool for studying the isotopic degree of freedom in heavy ion collisions
  • Wuenschel, S.; Hagel, K.; Wada, R.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 604, Issue 3 https://doi.org/10.1016/j.nima.2009.03.187
journal June 2009
Calibration and characterization of the IceCube photomultiplier tube
  • Abbasi, R.; Abdou, Y.; Abu-Zayyad, T.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 618, Issue 1-3 https://doi.org/10.1016/j.nima.2010.03.102
journal June 2010
STARS/LiBerACE: Segmented silicon and high-purity germanium detector arrays for low-energy nuclear reaction and structure studies
  • Lesher, S. R.; Phair, L.; Bernstein, L. A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 621, Issue 1-3 https://doi.org/10.1016/j.nima.2010.04.017
journal September 2010
Large-scale gadolinium-doped water Cherenkov detector for nonproliferation
  • Sweany, M.; Bernstein, A.; Bowden, N. S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 654, Issue 1 https://doi.org/10.1016/j.nima.2011.06.049
journal October 2011
A water-based neutron detector as a well multiplicity counter
  • Dazeley, S.; Asghari, A.; Bernstein, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 771 https://doi.org/10.1016/j.nima.2014.10.028
journal January 2015
The hyperion particle-γ detector array
  • Hughes, R. O.; Burke, J. T.; Casperson, R. J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 856 https://doi.org/10.1016/j.nima.2017.03.012
journal June 2017
Measurement of the Am 240 ( n , f ) cross section using the surrogate-ratio method journal September 2014
Compound-nuclear reaction cross sections from surrogate measurements journal March 2012
Reevaluation of Prompt Neutron Emission Multiplicity Distributions for Spontaneous Fission journal October 2008
Prompt Neutron Emission Probabilities Following Spontaneous and Thermal Neutron Fission journal September 1985

Cited By (1)