Should the Standard Count Be Excluded from Neutron Probe Calibration?

Journal Article · · Soil Science Society of America Journal
About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1406794
Report Number(s):
PNNL-SA-123951; 830403000
Journal Information:
Soil Science Society of America Journal, Journal Name: Soil Science Society of America Journal Journal Issue: 5 Vol. 81; ISSN 0361-5995
Publisher:
Alliance of Crop, Soil, and Environmental Science Societies
Country of Publication:
United States
Language:
English

Similar Records

Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes
Technical Report · Sat Aug 01 00:00:00 EDT 2009 · OSTI ID:982969

MANUFACTURE AND CALIBRATION OF NR PRIMARY PHYSICAL STANDARDS FOR ALPHA COUNTING
Technical Report · Wed Nov 30 23:00:00 EST 1960 · OSTI ID:4097614

Effects of gypsum on the neutron probe calibration curve
Journal Article · Thu Sep 01 00:00:00 EDT 1994 · Soil Science; (United States) · OSTI ID:6650792