Uranium hexafluoride liquid thermal expansion, elusive eutectic with hydrogen fluoride, and very first production using chlorine trifluoride

Conference ·
OSTI ID:139622
 [1]
  1. Central Environmental, Inc., Anchorage, AK (United States)
Three unusual incidents and case histories involving uranium hexafluoride in the enrichment facilities of the USA in the late 1940`s and early 1950`s are presented. The history of the measurements of the thermal expansion of liquids containing fluorine atoms within the molecule is reviewed with special emphasis upon uranium hexafluoride. A comparison is made between fluorinated esters, fluorocarbons, and uranium hexafluoride. The quantitative relationship between the thermal expansion coefficient, a, of liquids and the critical temperature, T{sub c} is presented. Uranium hexafluoride has an a that is very high in a temperature range that is used by laboratory and production workers - much higher than any other liquid measured. This physical property of UF{sub 6} has resulted in accidents involving filling the UF{sub 6} containers too full and then heating with a resulting rupture of the container. Such an incident at a uranium gaseous diffusion plant is presented. Production workers seldom {open_quotes}see{close_quotes} uranium hexafluoride. The movement of UF{sub 6} from one container to another is usually trailed by weight, not sight. Even laboratory scientists seldom {open_quotes}see{close_quotes} solid or liquid UF{sub 6} and this can be a problem at times. This inability to {open_quotes}see{close_quotes} the UF{sub 6}-HF mixtures in the 61.2{degrees}C to 101{degrees}C temperature range caused a delay in the understanding of the phase diagram of UF{sub 6}-HF which has a liquid - liquid immiscible region that made the eutectic composition somewhat elusive. Transparent fluorothene tubes solved the problem both for the UF{sub 6}-HF phase diagram as well as the UF{sub 6}-HF-CIF{sub 3} phase diagram with a miscibility gap starting at 53{degrees}C. The historical background leading to the first use of CIF{sub 3} to produce UF{sub 6} in both the laboratory and plant at K-25 is presented.
Research Organization:
Oak Ridge National Lab., TN (United States)
OSTI ID:
139622
Report Number(s):
CONF-9110117--; ON: DE92005283
Country of Publication:
United States
Language:
English

Similar Records

THE TREATMENT OF IRRADIATED FUELS BY NON-AQUEOUS METHODS
Journal Article · Wed Oct 31 23:00:00 EST 1962 · Bull. Inform. Sci. Tech. (Paris) · OSTI ID:4735092

Cover-gas and air buoyancy correction for the gravimetric analysis of uranium in uranium hexafluoride
Technical Report · Sat Feb 28 23:00:00 EST 1981 · OSTI ID:6591960

Generic report on health effects for the US Gaseous Diffusion Plants. Sect. 8, Pt. 1
Technical Report · Fri Jun 01 00:00:00 EDT 1984 · OSTI ID:6748017