Removal of Dissolved Silica using Calcinated Hydrotalcite in Real-life Applications.

Technical Report ·
DOI:https://doi.org/10.2172/1390475· OSTI ID:1390475

Water shortages are a growing global problem. Reclamation of industrial and municipal wastewater will be necessary in order to mitigate water scarcity. However, many operational challenges, such as silica scaling, prevent large scale water reuse. Previously, our team at Sandia has demonstrated the use of selective ion exchange materials, such as calcinated hydrotalcite (HTC, (Mg 6 Al 2 (OH) 16 (CO 3 )*4H 2 O)), for the low cost removal of silica from synthetic cooling tower water. However, it is not currently know if calcinated HTC has similar capabilities in realistic applications. The purpose of this study was to investigate the ability of calcinated HTC to remove silica from real cooling tower water. This was investigated under both batch and continuous conditions, and in the presence of competing ions. It was determined that calcinated HTC behaved similarly in real and synthetic cooling tower water; the HTC is highly selective for the silica even in the presence of competing cations. Therefore, the data concludes that calcinated HTC is a viable anti-scaling pretreatment for the reuse of industrial wastewaters.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1390475
Report Number(s):
SAND2017--9566; 656801
Country of Publication:
United States
Language:
English

Similar Records

Exceptional selectivity for dissolved silicas in industrial waters using mixed oxides
Journal Article · Mon Nov 06 23:00:00 EST 2017 · Journal of Water Process Engineering · OSTI ID:1411608

Waste Water for Power Generation via Energy Efficient Selective Silica Separations
Technical Report · Fri Sep 01 00:00:00 EDT 2017 · OSTI ID:1395755

Removing Dissolved Silica from Waste Water with Catechol and Active Carbon