skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Site status monitoring report for Underground Storage Tank 2331-U at Building 9201-1

Technical Report ·
DOI:https://doi.org/10.2172/137445· OSTI ID:137445

Building 9201-1 Site is located within the south central portion of the Oak Ridge Y-12 Plant; it was previously the location of a 560-gallon gasoline underground storage tank, which was excavated and removed after being suspected of leaking in 1988. This document presents potentiometric, groundwater quality and vapor monitoring data required for site status monitoring which was conducted as part of a Monitoring Only program approved by the Tennessee Dept. of Environment and Conservation. The document is divided into: introductory information, results of measurement and sampling of monitoring wells, and vapor monitoring data from subsurface utilities at the site.

Research Organization:
Oak Ridge Y-12 Plant (Y-12), Oak Ridge, TN (United States); Science Applications International Corp., Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
137445
Report Number(s):
Y/SUB-96-99069C/Y22/1; ON: DE96003415
Resource Relation:
Other Information: PBD: Oct 1995
Country of Publication:
United States
Language:
English