skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Experimental calibration procedures for rotating Lorentz-force flowmeters

Journal Article · · Measurement Science and Technology

Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.

Research Organization:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC02-09CH11466
OSTI ID:
1373697
Journal Information:
Measurement Science and Technology, Vol. 28, Issue 8; ISSN 0957-0233
Publisher:
IOP PublishingCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 4 works
Citation information provided by
Web of Science

References (18)

Sodium flow measurement in large pipelines of sodium cooled fast breeder reactors with bypass type flow meters journal January 2016
A review on the application of liquid metals as heat transfer fluid in Concentrated Solar Power technologies journal May 2016
Review of heat transfer fluids in tube-receivers used in concentrating solar thermal systems: Properties and heat transfer coefficients journal March 2016
Lorentz Force Flowmeter for Liquid Aluminum: Laboratory Experiments and Plant Tests journal February 2011
Local Lorentz force flowmeter at a continuous caster model using a new generation multicomponent force and torque sensor journal May 2016
Calibration of the Lorentz force flowmeter journal June 2011
The magnetic flywheel flow meter: Theoretical and experimental contributions journal June 2014
Optimal magnet configurations for Lorentz force velocimetry in low conductivity fluids journal May 2013
Spatially resolved measurements in a liquid metal flow with Lorentz force velocimetry journal June 2013
Investigation on frictional characteristic of deep-groove ball bearings subjected to radial loads journal June 2015
Analysis of the Journal Bearing Friction Losses in a Heavy-Duty Diesel Engine journal April 2015
Method for quick prediction of windage power loss journal April 2015
Application of IR imaging for free-surface velocity measurement in liquid-metal systems journal January 2017
A liquid metal flume for free surface magnetohydrodynamic experiments journal January 2008
GaInSn usage in the research laboratory journal May 2008
The uncertainty of a result from a linear calibration journal January 2006
Experimental calibration procedures for rotating Lorentz-force flowmeters dataset January 2017
Method for Quick Prediction of Windage Power Loss conference August 2014

Cited By (4)

Liquid Metal Diagnostics journal November 2019
Calibrationless rotating Lorentz-force flowmeters for low flow rate applications journal May 2018
Numerical calibration of a Lorentz force particle analyzer journal November 2018
Experimental calibration procedures for rotating Lorentz-force flowmeters dataset January 2017

Similar Records

Experimental calibration procedures for rotating Lorentz-force flowmeters
Dataset · Sun Jan 01 00:00:00 EST 2017 · OSTI ID:1373697

Calibrationless rotating Lorentz-force flowmeters for low flow rate applications
Journal Article · Tue May 29 00:00:00 EDT 2018 · Measurement Science and Technology · OSTI ID:1373697

Calibrationless rotating Lorentz-force flowmeters for low flow rate applications
Dataset · Tue May 29 00:00:00 EDT 2018 · OSTI ID:1373697