Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Long-Term Heating to Improve Receiver Performance

Conference ·
DOI:https://doi.org/10.1063/1.4984330· OSTI ID:1372039

The buildup of hydrogen in the heat transfer fluid (HTF) that circulates through components of parabolic trough power plants decreases receiver thermal efficiency, and ultimately, it decreases plant performance and electricity output. The generation and occurrence of hydrogen in the HTF provides the driving force for hydrogen to permeate from the HTF through the absorber tube wall and into the receiver annulus. Getters adsorb hydrogen from the annulus volume until they saturate and are no longer able to maintain low hydrogen pressure. The increase in hydrogen pressure within the annulus significantly degrades thermal performance of the receiver and decreases overall power-plant efficiency. NREL and Acciona Energy North America (Acciona) are developing a method to control the levels of dissolved hydrogen in the circulating HTF. The basic approach is to remove hydrogen from the expansion tanks of the HTF subsystem at a rate that maintains hydrogen in the circulating HTF to a target level. Full-plant steady-state models developed by the National Renewable Energy Laboratory (NREL) predict that if hydrogen is removed from the HTF within the expansion tanks, the HTF that circulates through the collector field remains essentially free of hydrogen until the HTF returns to the power block in the hot headers. One of the key findings of our modeling is the prediction that hydrogen will reverse-permeate out of the receiver annulus if dissolved hydrogen in the HTF is kept sufficiently low. To test this prediction, we performed extended heating of an in-service receiver that initially had high levels of hydrogen in its annulus. The heating was performed using NREL's receiver test stand. Results of our testing showed that receiver heat loss steadily decreased with daily heating, resulting in a corresponding improvement in receiver thermal efficiency.

Research Organization:
National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Solar Energy Technologies Office (EE-4S)
DOE Contract Number:
AC36-08GO28308
OSTI ID:
1372039
Report Number(s):
NREL/CP-5500-66772
Country of Publication:
United States
Language:
English

References (3)

Techno-economic analysis of receiver replacement scenarios in a parabolic trough field
  • Röger, Marc; Lüpfert, Eckhard; Caron, Simon
  • SOLARPACES 2015: International Conference on Concentrating Solar Power and Chemical Energy Systems, AIP Conference Proceedings https://doi.org/10.1063/1.4949082
conference January 2016
Techniques for Reducing Thermal Conduction and Natural Convection Heat Losses in Annular Receiver Geometries journal February 1979
Heat Conduction of Inert Gas-Hydrogen Mixtures in Parabolic Trough Receivers
  • Burkholder, Frank; Brandemuehl, Michael; Kutscher, Chuck
  • ASME 2008 2nd International Conference on Energy Sustainability collocated with the Heat Transfer, Fluids Engineering, and 3rd Energy Nanotechnology Conferences, ASME 2008 2nd International Conference on Energy Sustainability, Volume 2 https://doi.org/10.1115/ES2008-54176
conference June 2009

Similar Records

Steady-State Plant Model to Predict Hydroden Levels in Power Plant Components
Conference · Tue Jun 27 00:00:00 EDT 2017 · OSTI ID:1372041

Hydrogen Mitigation Process Testing at Nevada Solar One
Conference · Thu May 12 00:00:00 EDT 2022 · OSTI ID:1874011

Acciona Power Plant Hydrogen Mitigation Project
Technical Report · Wed Apr 01 00:00:00 EDT 2020 · OSTI ID:1659801