Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Testing of the HP G-link chip set for an event builder application

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.467775· OSTI ID:136921
; ; ; ;  [1]
  1. Fermi National Accelerator Lab., Batavia, IL (United States)
The Hewlett Packard HDMP-1000 G-Link transmitter and receiver chip set was tested for an event builder application. The re-lock time of the serial link when a data path is changed is less than 30 {micro}s provided fill frames are transmitted. With a 1 kHz data path switching rate, this results in less than a 3% data rate inefficiency due to re-synchronization, which makes the HP G-Link chip set effective for use in a large event builder for a hadron collider experiment.
OSTI ID:
136921
Report Number(s):
CONF-941061--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 4Pt1 Vol. 42; ISSN IETNAE; ISSN 0018-9499
Country of Publication:
United States
Language:
English