Title: Corrosion Testing of 304L SS 3013 Inner Container and Teardrop Samples

Technical Report ·
DOI:https://doi.org/10.2172/1367811· OSTI ID:1367811

The Department of Energy (DOE) 3013 Standard specifies a minimum of two containers to be used for the storage of plutonium-bearing materials containing at least 30 wt.% plutonium and uranium. Three nested containers are typically used, the outer, inner, and convenience containers, shown in Figure 1. Both the outer and inner containers are sealed with a weld while the innermost convenience container must not be sealed. Lifetime of the containers is expected to be fifty years. The containers are fabricated of austenitic stainless steels (SS) due to their high corrosion resistance. Potential failure mechanisms of the storage containers have been examined by Kolman and Lillard et al.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC52-06NA25396
OSTI ID:
1367811
Report Number(s):
LA-UR-17-25141
Country of Publication:
United States
Language:
English

Similar Records

He Leak Testing of 3013 Inner Container Lids
Technical Report · Tue Feb 13 00:00:00 EST 2024 · OSTI ID:1367811

Residual Stresses and Other Properties of Teardrops
Technical Report · Wed Jul 26 00:00:00 EDT 2017 · OSTI ID:1367811

CLOSURE WELD DEVELOPMENT FOR 3013 OUTER CONTAINERS
Journal Article · Tue Nov 10 00:00:00 EST 2009 · Journal of Nuclear Materials Management · OSTI ID:1367811