Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

The Impact of Operating Parameters and Correlated Parameters for Extended BWR Burnup Credit

Technical Report ·
DOI:https://doi.org/10.2172/1366400· OSTI ID:1366400

Applicants for certificates of compliance for spent nuclear fuel (SNF) transportation and dry storage systems perform analyses to demonstrate that these systems are adequately subcritical per the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Parts 71 and 72. For pressurized water reactor (PWR) SNF, these analyses may credit the reduction in assembly reactivity caused by depletion of fissile nuclides and buildup of neutron-absorbing nuclides during power operation. This credit for reactivity reduction during depletion is commonly referred to as burnup credit (BUC). US Nuclear Regulatory Commission (NRC) staff review BUC analyses according to the guidance in the Division of Spent Fuel Storage and Transportation Interim Staff Guidance (ISG) 8, Revision 3, Burnup Credit in the Criticality Safety Analyses of PWR Spent Fuel in Transportation and Storage Casks.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1366400
Report Number(s):
ORNL/TM-2017/46
Country of Publication:
United States
Language:
English

Similar Records

Regulatory perspective of boiling water reactor peak reactivity credit in spent fuel storage and transportation - 14592
Conference · Tue Sep 15 00:00:00 EDT 2015 · OSTI ID:23100951

Parametric Study of the Effect of Burnable Poison Rods for PWR Burnup Credit
Technical Report · Thu Sep 27 20:00:00 EDT 2001 · OSTI ID:814219

Addressing Fission Product Validation in MCNP Burnup Credit Criticality Calculations