Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [2];  [2];  [2];  [2];  [2];  [2];  [3];  [3]
  1. University of Michigan, Ann Arbor, MI (United States); Department of Nuclear Engineering and Radiological Sciences, University of Michigan
  2. University of Michigan, Ann Arbor, MI (United States)
  3. European Commission, Ispra (Italy)
Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.
Research Organization:
University of Michigan, Ann Arbor, MI (United States)
Sponsoring Organization:
USDOE Office of Science (SC); National Science Foundation (NSF); US Department of Homeland Security
Grant/Contract Number:
NA0002534; FG52-10NA29654
OSTI ID:
1365712
Alternate ID(s):
OSTI ID: 22419510
OSTI ID: 1556644
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Issue: C Vol. 767; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (7)

ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and Technology journal December 2006
Identification of shielded neutron sources with the liquid scintillator BC-501A using a digital pulse shape discrimination method
  • Flaska, M.; Pozzi, S. A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 577, Issue 3 https://doi.org/10.1016/j.nima.2007.04.141
journal July 2007
Pulse-height distributions of neutron and gamma rays from plutonium-oxide samples
  • Pozzi, S. A.; Clarke, S. D.; Flaska, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 608, Issue 2 https://doi.org/10.1016/j.nima.2009.07.007
journal September 2009
Plastic scintillators with efficient neutron/gamma pulse shape discrimination
  • Zaitseva, Natalia; Rupert, Benjamin L.; PaweŁczak, Iwona
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 668, p. 88-93 https://doi.org/10.1016/j.nima.2011.11.071
journal March 2012
Pulse shape discrimination in the plastic scintillator EJ-299-33
  • Pozzi, S. A.; Bourne, M. M.; Clarke, S. D.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 723 https://doi.org/10.1016/j.nima.2013.04.085
journal September 2013
Radioluminescent characteristics of the EJ 299-33 plastic scintillator
  • Nyibule, S.; Henry, E.; Schröder, W. U.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 728 https://doi.org/10.1016/j.nima.2013.06.020
journal November 2013
Experimental tests of the new plastic scintillator with pulse shape discrimination capabilities EJ-299-33
  • Cester, D.; Nebbia, G.; Stevanato, L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 735 https://doi.org/10.1016/j.nima.2013.09.031
journal January 2014

Figures / Tables (8)


Similar Records

Cross-correlation measurements with the EJ-299-33 plastic scintillator
Journal Article · Fri Oct 31 00:00:00 EDT 2014 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1487033

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass
Journal Article · Tue Nov 10 23:00:00 EST 2020 · Journal of Instrumentation · OSTI ID:1716594