Evaluation of the Frequency for Gas Sampling for the High Burnup Confirmatory Data Project
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
This report provides a technically based gas sampling frequency strategy for the High Burnup (HBU) Confirmatory Data Project. The evaluation of: 1) the types and magnitudes of gases that could be present in the project cask and, 2) the degradation mechanisms that could change gas compositions culminates in an adaptive gas sampling frequency strategy. This adaptive strategy is compared against the sampling frequency that has been developed based on operational considerations.
- Research Organization:
- Idaho National Laboratory (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE Office of Nuclear Energy (NE)
- DOE Contract Number:
- AC07-05ID14517;
- OSTI ID:
- 1364086
- Report Number(s):
- INL/EXT--15-35368
- Country of Publication:
- United States
- Language:
- English