skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Neutron imaging of diabatic two-phase flows relevant to air conditioning

Conference ·
OSTI ID:1361338

The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution will have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center (BTRIC); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). High Flux Isotope Reactor (HFIR)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1361338
Resource Relation:
Conference: 12th IEA Heat Pump Conference, Rotterdam, Netherlands, 20170515, 20170518
Country of Publication:
United States
Language:
English

Similar Records

Neutron Imaging of a Two-Phase Refrigerant Flow
Conference · Thu Jan 01 00:00:00 EST 2015 · OSTI ID:1361338

Evaporation heat transfer and pressure drop of refrigerant R-134a in a plate heat exchanger
Journal Article · Mon Feb 01 00:00:00 EST 1999 · Journal of Heat Transfer · OSTI ID:1361338

Addressing Two-Phase Flow Maldistribution in Microchannel Heat and Mass Exchangers
Journal Article · Mon Jul 23 00:00:00 EDT 2018 · Journal of Heat Transfer · OSTI ID:1361338

Related Subjects