Title: Survey of Neutron Generators for Active Interrogation

Technical Report ·
DOI:https://doi.org/10.2172/1356115· OSTI ID:1356115
 [1];  [1];  [1];  [2];  [2]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
  2. Idaho National Lab. (INL), Idaho Falls, ID (United States)

Some of these commercially available generators meet all of the requirements in Table 1, but there are other concerns. Most generators containing SF6 will be required to have the SF6 gas removed for shipping because of DOT regulations. However, Thermo Fisher has a DOT exemption. The P211 and B211 from Thermo Fisher meet the requirements listed in Table 1, but they are old designs and are no longer offered for sale. Also, they require 15 minutes or more of warmup before neutron output is available, and they lack a modern digital control. The nGen-300C from Starfire Industries is interesting because it is a portable system, but it uses the DD reaction for 2.5 MeV neutrons, which are not as penetrating as the 14 MeV neutrons from the DT reaction. The MP 320 from Thermo Fisher is another portable system, but the minimum pulse rate is 250 Hz, which is too fast for measurement of delayed neutrons and re-interrogation by delayed neutrons between pulses. The Genie 16 from Sodern (from France) probably meets the requirements, but the required power is probably too high for battery operation. The generators from Russia and China may be difficult to purchase, and service may not be available. The power required by some of these generators is low enough that batteries can be used. The portable units, nGen-300C and the MP320, could easily be operated with batteries. Other generators with low power requirements, as specified in the above vendors list, could possibly be operated with reason size batteries. The batteries do not need to be internal to the generator, but can be in a separate package. The availability of high capacity lithium batteries with sophisticated safety circuits makes battery operation more possible now than when lead acid batteries were used. The best path forward probably requires working with vendors of the existing systems. If Starfire Industries could be persuaded to put tritium in their nGen-300C generator, possibly in collaboration with a national laboratory, this would provide the 14-MeV neutrons needed. Another possibility is a modification of the Thermo Fisher MP 320 to run at 50 to 100 Hz. More discussions with these vendors, and possibly others, are required to determine their interest and possible costs.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC52-06NA25396
OSTI ID:
1356115
Report Number(s):
LA-UR-17-23592
Country of Publication:
United States
Language:
English

Similar Records

Mercury Calibration System
Technical Report · Wed Mar 11 00:00:00 EDT 2009 · OSTI ID:1356115

Mercury Calibration System
Technical Report · Wed Mar 11 00:00:00 EDT 2009 · OSTI ID:1356115

Field evaluation of remote wind sensing technologies: Shore-based and buoy mounted LIDAR systems
Technical Report · Fri Nov 03 00:00:00 EDT 2017 · OSTI ID:1356115