Activation analysis for ITER design options
Conference
·
OSTI ID:135552
This paper presents a summary of the activation analyses that have been performed for the shielding blanket (SS/water) and for the breeding blanket (Li/V) of ITER design options. The activation code RACC-P, which has been modified for pulsed operation, has been used in these calculations. The spatial distributions of the radioactive inventory, decay heat, biological hazard potential, and the contact dose were calculated for the two designs for different operation modes and targeted fluences. A one-dimensional toroidal cylindrical geometrical model has been utilized to determine the neutron fluxes in the two designs. The results are normalized for an inboard and outboard neutron wall loadings of 0.91 and 1.2 MW/m{sup 2} respectively.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 135552
- Report Number(s):
- ANL/TD/CP--86631; CONF-950905--7; ON: DE96002502
- Country of Publication:
- United States
- Language:
- English
Similar Records
Summary report for ITER Task -- D4: Activation calculations for the stainless steel ITER design
Summary report for ITER task - D4: Activation calculations for the lithium vanadium ITER design
Shielding analysis for the ITER divertor and vacuum pumping ducts
Technical Report
·
Tue Jan 31 23:00:00 EST 1995
·
OSTI ID:97164
Summary report for ITER task - D4: Activation calculations for the lithium vanadium ITER design
Technical Report
·
Tue Jan 31 23:00:00 EST 1995
·
OSTI ID:93722
Shielding analysis for the ITER divertor and vacuum pumping ducts
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:197078