The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements
Conference
·
OSTI ID:1343074
This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.
- Research Organization:
- National Renewable Energy Laboratory (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Solar Energy Technologies Office (EE-4S)
- DOE Contract Number:
- AC36-08GO28308;
- OSTI ID:
- 1343074
- Report Number(s):
- NREL/PO-5D00-66668; MainId:12660; UUID:157fd1a1-ed33-e611-a722-d89d67132a6d; MainAdminID:1140
- Conference Information:
- Presented at the European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), 20-24 June 2016, Munich, Germany
- Country of Publication:
- United States
- Language:
- English
Similar Records
Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective
The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint
Calibration procedure of Hukseflux SR25 to Establish the Diffuse Reference for the Outdoor Broadband Radiometer Calibration
Conference
·
Sun Nov 20 23:00:00 EST 2016
·
OSTI ID:1343659
The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint
Conference
·
Thu Jun 30 20:00:00 EDT 2016
·
OSTI ID:1270785
Calibration procedure of Hukseflux SR25 to Establish the Diffuse Reference for the Outdoor Broadband Radiometer Calibration
Technical Report
·
Mon Jul 31 20:00:00 EDT 2017
·
OSTI ID:1378901