Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Plastic scintillators relative gamma-ray light yield measurement

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4978288· OSTI ID:1333614

Here we are investigating the inclusion of organotin compounds in polystyrene material to improve plastic scintillators full gamma-ray energy sensitivity with the ultimate goal of achieving spectroscopy. Accurate evaluation of the relative light yield from the newly developed scintillators is crucial to assess merits of compounds and chemical processes used in the scintillators development and assess the scintillation efficiencies of the newly produced scintillators. Full gamma-ray energy peak in the measured gamma-ray spectrum, resulting from total absorption of gamma-ray energy, would be ideal in assessing the relative light yield. However, the significant number of new samples we are producing for investigation lead us to the possibility of using the Compton edge as an alternate spectral feature that can be exploited for expeditious characterization of the relative light yield in plastic scintillators. In this study we present a spectra gain matching approach, using a spectrum rebinning, for accurate relative light yield measurement using the Compton edge.

Research Organization:
Sandia National Laboratories (SNL-CA), Livermore, CA (United States)
Sponsoring Organization:
DHS-DNDO; USDOE
Grant/Contract Number:
AC04-94AL85000
OSTI ID:
1333614
Report Number(s):
SAND--2016-7956J; 646658
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 3 Vol. 88; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
English

References (23)

The use of organometallic compounds in plastic scintillators for the detection and resolution of gamma rays journal October 1965
A new method of determining the compton edge in liquid scintillators journal February 1973
Fast calibration of large Si(Li) electron detectors from 511.0 to 4564.0 keV using double-escape peaks and compton edges from 66Ga journal August 1974
Gamma-calibration of NE 213 scintillation counters journal March 1982
Gamma calibration of organic scintillators
  • Cherubini, R.; Moschini, G.; Nino, R.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 281, Issue 2 https://doi.org/10.1016/0168-9002(89)91332-6
journal September 1989
Compton edge energy calibration of organic detectors
  • Hristova, A. V.; Vapirev, E. I.; Tsankov, L. T.
  • International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, Vol. 41, Issue 9 https://doi.org/10.1016/0883-2889(90)90068-r
journal January 1990
Development of tin-loaded liquid scintillator for the double beta decay experiment
  • Hwang, M. J.; Kwon, Y. J.; Kim, H. J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 570, Issue 3 https://doi.org/10.1016/j.nima.2006.10.100
journal January 2007
Energy calibration of gamma spectra in plastic scintillators using Compton kinematics
  • Siciliano, E. R.; Ely, J. H.; Kouzes, R. T.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 594, Issue 2 https://doi.org/10.1016/j.nima.2008.06.031
journal September 2008
Compton-edge-based energy calibration of double-sided silicon strip detectors in Compton camera
  • Seo, Hee; Park, Jin Hyung; Kim, Chan Hyeong
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 633 https://doi.org/10.1016/j.nima.2010.06.138
journal May 2011
A measurement method of a detector response function for monochromatic electrons based on the Compton scattering
  • Bakhlanov, S. V.; Bazlov, N. V.; Derbin, A. V.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 821 https://doi.org/10.1016/j.nima.2016.03.054
journal June 2016
Measurement of Compton edge position in low-Z scintillators journal March 2010
Energy calibration of plastic scintillators for low energy electrons by using Compton scatterings of γ rays journal June 1999
Influence of bismuth loading in polystyrene-based plastic scintillators for low energy gamma spectroscopy journal January 2014
The Scintillation Counter as a Low Resolution Gamma‐Ray Spectrometer journal March 1950
Slow neutron-induced activity in gold
  • Siegbahn, Karl Manne Georg
  • Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, Vol. 189, Issue 1019, p. 527-535 https://doi.org/10.1098/rspa.1947.0055
journal June 1947
Alkali Halide Scintillation Counters journal July 1948
The measured electron response nonproportionalities of CaF/sub 2/, BGO, and LSO journal June 1997
A simple method of energy calibration for thin plastic scintillator journal January 2001
Geant4 developments and applications journal February 2006
Energy calibration of NE-213 scintillation counters by δ-rays journal February 1979
Measurements of NaI(Tl) Electron Response: Comparison of Different Samples journal February 2009
Distance Dependent Quenching and Gamma-Ray Spectroscopy in Tin-Loaded Polystyrene Scintillators journal February 2016
Bismuth-loaded plastic scintillators for gamma-ray spectroscopy journal January 2012

Similar Records

Plastic Scintillators Light Yield Energy Calibration.
Journal Article · Mon Nov 30 23:00:00 EST 2015 · OSTI ID:1427195

Gamma spectrometry and plastic-scintillator inherent background
Journal Article · Sun Jan 31 23:00:00 EST 1988 · Sov. At. Energy (Engl. Transl.); (United States) · OSTI ID:6907229

Metal-loaded plastic scintillators for gamma-ray spectroscopy
Patent · Tue Jul 17 00:00:00 EDT 2018 · OSTI ID:1464622