Design of a Large Bore 60-T Pulse Magnet for Sandia National Laboratories

Conference ·
OSTI ID:13071

The design of a new pulsed magnet system for the generation of intense electron beams is presented. Determined by the required magnetic field profile along the axis, the magnet system consists of two coils (Coil No.1 and No.2) separated by a 32-mm axial gap. Each coil is energized independently. Both coils are internally reinforced with HIM Zylon fiber/epoxy composite. Coil No.1 made with AI-15 Glidcop wire has a bore of 110-mm diameter and is 200-mm long; it is energized by a 1.3-MJ, 13-kV capacitor bank. The magnetic field at the center of this coil is 30 T. Coil No.2 made with CuNb wire has a bore of 45 mm diameter, generates 60 T with a pulse duration of 60 ms, and is powered by a 4.0-MJ, 17.7-kV capacitor bank. We present design criteria, the coupling of the magnets, and the normal and the fault conditions during operation.

Research Organization:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
13071
Report Number(s):
SAND99-1655C
Country of Publication:
United States
Language:
English

Similar Records

The New High Magnetic Field Laboratory at Dresden: a Pulsed-Field Laboratory at an IR Free-Electron-Laser
Journal Article · Thu Sep 07 00:00:00 EDT 2006 · AIP Conference Proceedings · OSTI ID:20877538

Design study of a 60 T pulsed magnet with 10 {micro}s risetime
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · IEEE Transactions on Magnetics · OSTI ID:287681

FIRST 100 T NON-DESTRUCTIVE MAGNET