Breakdown voltage of metal-oxide resistors in liquid argon
- Fermilab
- Kansas State U.
- MIT
- Pittsburgh U.
- Bern U., LHEP
We characterized a sample of metal-oxide resistors and measured their breakdown voltage in liquid argon by applying high voltage (HV) pulses over a 3 second period. This test mimics the situation in a HV-divider chain when a breakdown occurs and the voltage across resistors rapidly rise from the static value to much higher values. All resistors had higher breakdown voltages in liquid argon than their vendor ratings in air at room temperature. Failure modes range from full destruction to coating damage. In cases where breakdown was not catastrophic, subsequent breakdown voltages were lower in subsequent measuring runs. One resistor type withstands 131 kV pulses, the limit of the test setup.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1296790
- Report Number(s):
- FERMILAB-PUB-14-286-E; arXiv:1408.4013; 1311332
- Journal Information:
- Journal of Instrumentation, Journal Name: Journal of Instrumentation Journal Issue: 11 Vol. 9; ISSN 1748-0221