Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Some studies of avalanche photodiode readout of fast scintillators

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.467822· OSTI ID:129147
;  [1];  [2];  [3];  [1];  [4]
  1. Max-Planck-Inst. fuer Physik, Muenchen (Germany)
  2. Inst. of Nuclear Physics, Krakow (Poland)
  3. Paul Scherrer Inst., Villigen (Switzerland)
  4. Budger Institute of Nuclear Physics, Novosibirsk (Russian Federation)

Photomultipliers (PMs) are the classical readout element for scintillation detectors in high energy particle physics, nuclear physics, medical physics, industrial radiation monitors etc. Here, large area avalanche photodiodes with high performance, narrow operation tolerances and high reliability have recently become available. The authors report on some tests of their performance in the readout of fast scintillators.

OSTI ID:
129147
Report Number(s):
CONF-941061--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 4Pt1 Vol. 42; ISSN IETNAE; ISSN 0018-9499
Country of Publication:
United States
Language:
English

Similar Records

BGO Readout with Photodiodes as a Soft gamma-Ray Detector at -30C
Technical Report · Thu Jan 20 23:00:00 EST 2005 · OSTI ID:839727

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers
Journal Article · Mon Jun 01 00:00:00 EDT 1998 · IEEE Transactions on Nuclear Science · OSTI ID:624169

Toward minimum ionizing particle detection using scintillating fibers and avalanche photodiodes
Conference · Fri Jun 01 00:00:00 EDT 1990 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) · OSTI ID:6610470