Title: Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2014

Technical Report ·
DOI:https://doi.org/10.2172/1260460· OSTI ID:1260460
 [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The TDP failure modes considered are failure to start (FTS), failure to run less than or equal to one hour (FTR=1H), failure to run more than one hour (FTR>1H), and normally running systems FTS and failure to run (FTR). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified for TDP unavailability, for frequency of start demands for standby TDPs, and for run hours in the first hour after start. Statistically significant decreasing trends were identified for start demands for normally running TDPs, and for run hours per reactor critical year for normally running TDPs.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1260460
Report Number(s):
INL/EXT-16-37938; TRN: US1601555
Country of Publication:
United States
Language:
English

Similar Records

Enhanced Component Performance Study: Turbine Driven Pumps 1998–2022
Technical Report · Sat Jul 01 00:00:00 EDT 2023 · OSTI ID:1260460

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020
Technical Report · Tue Mar 01 00:00:00 EST 2022 · OSTI ID:1260460

Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2018
Technical Report · Fri Apr 17 00:00:00 EDT 2020 · OSTI ID:1260460