Title: Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample

Technical Report ·
DOI:https://doi.org/10.2172/1254421· OSTI ID:1254421
 [1];  [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-270-271-272), pulled on 02/21/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-270-271-272 indicated the IsoparTML concentration is above its nominal level (101%). The modifier (CS-7SB), the extractant (MaxCalix), and the TiDG concentrations are 7%, 6%, and 40% below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, IsoparTML, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC09-08SR22470
OSTI ID:
1254421
Report Number(s):
SRNL-STI-2016-00194