Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors
- Univ. of Michigan, Ann Arbor, MI (United States)
- Ohio Univ., Athens, OH (United States)
Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for the light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.
- Research Organization:
- Ohio Univ., Athens, OH (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Nuclear Physics (NP); USDOE Office of Nuclear Energy (NE)
- Contributing Organization:
- Univ. of Michigan, Ann Arbor, MI (United States); Ohio Univ., Athens, OH (United States)
- Grant/Contract Number:
- FG02-88ER40387
- OSTI ID:
- 1253950
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 715, Issue C; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Web of Science
Inelastic neutron scattering and prompt fission neutron spectra for 237Np
|
journal | December 2000 |
A Measurement of the 27 Al ( d, n ) Spectrum for Use in Neutron Detector Calibration
|
journal | June 1998 |
MCNPX-PoliMi for nuclear nonproliferation applications
|
journal | December 2012 |
The Ohio University beam swinger facility
|
journal | July 1982 |
Total characterization of neutron detectors with a 252Cf source and a new light output determination
|
journal | February 2009 |
Calculation of the light pulse distributions induced by fast neutrons in organic scintillation detectors
|
journal | June 2010 |
Analysis of neutron and photon detection position for the calibration of plastic (BC-420) and liquid (BC-501) scintillators
|
journal | May 2004 |
Detection of energetic heavy ions
|
journal | April 1972 |
Optimizing the energy resolution of scintillation counters at high energies
|
journal | February 1980 |
Fast neutron spectrometry with organic scintillators applied to magnetic fusion experiments
|
journal | January 2002 |
Calibration of BC501A liquid scintillator cells with monochromatic neutron beams
|
journal | December 1998 |
Proton light yield in organic scintillators using a double time-of-flight technique
|
journal | July 2018 |
Extension of the neutron scatter camera sensitivity to the ∼10–200 MeV neutron energy range
|
journal | May 2019 |
Imaging Special Nuclear Material using a Handheld Dual Particle Imager
|
journal | February 2020 |
Evaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of channels
|
journal | April 2014 |
Similar Records
Light output response of EJ-309 liquid organic scintillator to 2.86–3.95 MeV carbon recoil ions due to neutron elastic and inelastic scatter
Neutron response characterization for an EJ299-33 plastic scintillation detector