skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [1];  [1];  [1];  [2]
  1. Univ. of Michigan, Ann Arbor, MI (United States)
  2. Ohio Univ., Athens, OH (United States)

Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for the light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.

Research Organization:
Ohio Univ., Athens, OH (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Nuclear Physics (NP); USDOE Office of Nuclear Energy (NE)
Contributing Organization:
Univ. of Michigan, Ann Arbor, MI (United States); Ohio Univ., Athens, OH (United States)
Grant/Contract Number:
FG02-88ER40387
OSTI ID:
1253950
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 715, Issue C; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 6 works
Citation information provided by
Web of Science

References (11)

Inelastic neutron scattering and prompt fission neutron spectra for 237Np journal December 2000
A Measurement of the 27 Al ( d, n ) Spectrum for Use in Neutron Detector Calibration journal June 1998
MCNPX-PoliMi for nuclear nonproliferation applications
  • Pozzi, S. A.; Clarke, S. D.; Walsh, W. J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 694 https://doi.org/10.1016/j.nima.2012.07.040
journal December 2012
The Ohio University beam swinger facility journal July 1982
Total characterization of neutron detectors with a 252Cf source and a new light output determination
  • Kornilov, N. V.; Fabry, I.; Oberstedt, S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 599, Issue 2-3 https://doi.org/10.1016/j.nima.2008.10.032
journal February 2009
Calculation of the light pulse distributions induced by fast neutrons in organic scintillation detectors
  • Enqvist, Andreas; Pázsit, Imre
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 618, Issue 1-3 https://doi.org/10.1016/j.nima.2010.02.119
journal June 2010
Analysis of neutron and photon detection position for the calibration of plastic (BC-420) and liquid (BC-501) scintillators
  • Pozzi, Sara A.; Mullens, James A.; Mihalczo, John T.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 524, Issue 1-3 https://doi.org/10.1016/j.nima.2003.12.036
journal May 2004
Detection of energetic heavy ions journal April 1972
Optimizing the energy resolution of scintillation counters at high energies journal February 1980
Fast neutron spectrometry with organic scintillators applied to magnetic fusion experiments
  • Kaschuck, Yu.A.; Esposito, B.; Trykov, L.A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 476, Issue 1-2, p. 511-515 https://doi.org/10.1016/S0168-9002(01)01499-1
journal January 2002
Calibration of BC501A liquid scintillator cells with monochromatic neutron beams
  • Arneodo, F.; Benetti, P.; Bettini, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 418, Issue 2-3 https://doi.org/10.1016/S0168-9002(98)00679-2
journal December 1998

Cited By (4)

Proton light yield in organic scintillators using a double time-of-flight technique journal July 2018
Extension of the neutron scatter camera sensitivity to the ∼10–200 MeV neutron energy range journal May 2019
Imaging Special Nuclear Material using a Handheld Dual Particle Imager journal February 2020
Evaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of channels journal April 2014

Similar Records

Evaluation of neutron light output response functions in EJ-309 organic scintillators
Journal Article · Tue Oct 25 00:00:00 EDT 2016 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1253950

Light output response of EJ-309 liquid organic scintillator to 2.86–3.95 MeV carbon recoil ions due to neutron elastic and inelastic scatter
Journal Article · Wed Dec 06 00:00:00 EST 2017 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1253950

Neutron response characterization for an EJ299-33 plastic scintillation detector
Journal Article · Sat May 10 00:00:00 EDT 2014 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1253950