Development of new VOC exposure metrics and their relationship to ''Sick Building Syndrome'' symptoms
- Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab., Berkeley, CA (United States)
Volatile organic compounds (VOCs) are suspected to contribute significantly to ''Sick Building Syndrome'' (SBS), a complex of subchronic symptoms that occurs during and in general decreases away from occupancy of the building in question. A new approach takes into account individual VOC potencies, as well as the highly correlated nature of the complex VOC mixtures found indoors. The new VOC metrics are statistically significant predictors of symptom outcomes from the California Healthy Buildings Study data. Multivariate logistic regression analyses were used to test the hypothesis that a summary measure of the VOC mixture, other risk factors, and covariates for each worker will lead to better prediction of symptom outcome. VOC metrics based on animal irritancy measures and principal component analysis had the most influence in the prediction of eye, dermal, and nasal symptoms. After adjustment, a water-based paints and solvents source was found to be associated with dermal and eye irritation. The more typical VOC exposure metrics used in prior analyses were not useful in symptom prediction in the adjusted model (total VOC (TVOC), or sum of individually identified VOCs (ΣVOCi)). Also not useful were three other VOC metrics that took into account potency, but did not adjust for the highly correlated nature of the data set, or the presence of VOCs that were not measured. High TVOC values (2--7 mg m-3) due to the presence of liquid-process photocopiers observed in several study spaces significantly influenced symptoms. Analyses without the high TVOC values reduced, but did not eliminate the ability of the VOC exposure metric based on irritancy and principal component analysis to explain symptom outcome.
- Research Organization:
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 125046
- Report Number(s):
- LBL--37652; ON: DE96004026
- Country of Publication:
- United States
- Language:
- English
Similar Records
The prevalence of symptoms associated with sick buildings and polluted industrial environments as compared to unexposed reference groups without expressed dissatisfaction
Associations of indoor carbon dioxide concentrations, VOCS, environmental susceptibilities with mucous membrane and lower respiratory sick building syndrome symptoms in the BASE study: Analyses of the 100 building dataset
Exposure of humans to a volatile organic mixture. 3. Inflammatory response
Journal Article
·
Sat Dec 31 23:00:00 EST 1988
· Environment International; (USA)
·
OSTI ID:6943113
Associations of indoor carbon dioxide concentrations, VOCS, environmental susceptibilities with mucous membrane and lower respiratory sick building syndrome symptoms in the BASE study: Analyses of the 100 building dataset
Technical Report
·
Tue Oct 01 00:00:00 EDT 2002
·
OSTI ID:806126
Exposure of humans to a volatile organic mixture. 3. Inflammatory response
Technical Report
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:7110471