Effects of chemo-mechanical polishing on CdZnTe X-ray and gamma-ray detectors

Journal Article · · Journal of Electronic Materials
 [1];  [2];  [3];  [1];  [2]
  1. Alabama A&M Univ., Normal, AL (United States); Brookhaven National Lab. (BNL), Upton, NY (United States)
  2. Brookhaven National Lab. (BNL), Upton, NY (United States)
  3. Alabama A&M Univ., Normal, AL (United States)
Here, mechanically polishing cadmium zinc telluride (CdZnTe) wafers for x-ray and gamma-ray detectors often is inadequate in removing surface defects caused by cutting them from the ingots. Fabrication-induced defects, such as surface roughness, dangling bonds, and nonstoichiometric surfaces, often are reduced through polishing and etching the surface. In our earlier studies of mechanical polishing with alumina powder, etching with hydrogen bromide in hydrogen peroxide solution, and chemomechanical polishing with bromine–methanol–ethylene glycol solution, we found that the chemomechanical polishing process produced the least surface leakage current. In this research, we focused on using two chemicals to chemomechanically polish CdZnTe wafers after mechanical polishing, viz. bromine–methanol–ethylene glycol (BME) solution, and hydrogen bromide (HBr) in a hydrogen peroxide and ethylene–glycol solution. We used x-ray photoelectron spectroscopy (XPS), current–voltage (I–V) measurements, and Am-241 spectral response measurements to characterize and compare the effects of each solution. The results show that the HBr-based solution produced lower leakage current than the BME solution. Results from using the same chemomechanical polishing solution on two samples confirmed that the surface treatment affects the measured bulk current (a combination of bulk and surface currents). XPS results indicate that the tellurium oxide to tellurium peak ratios for the mechanical polishing process were reduced significantly by chemomechanical polishing using the BME solution (78.9% for Te 3d5/2O2 and 76.7% for Te 3d3/2O2) compared with the HBr-based solution (27.6% for Te 3d5/2O2 and 35.8% for Te 3d3/2O2). Spectral response measurements showed that the 59.5-keV peak of Am-241 remained under the same channel number for all three CdZnTe samples. While the BME-based solution gave a better performance of 7.15% full-width at half-maximum (FWHM) compared with 7.59% FWHM for the HBr-based solution, the latter showed a smaller variation in performance of 0.39% FWHM over 7 days compared with 0.69% for the BME-based solution.
Research Organization:
Brookhaven National Laboratory (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Nonproliferation and Verification Research and Development (NA-22)
OSTI ID:
1244209
Report Number(s):
BNL--108514-2015-JA; NN2001
Journal Information:
Journal of Electronic Materials, Journal Name: Journal of Electronic Materials Journal Issue: 9 Vol. 44; ISSN 0361-5235
Publisher:
SpringerCopyright Statement
Country of Publication:
United States
Language:
English

References (16)

Surface passivation of cadmium zinc telluride radiation detectors by potassium hydroxide solution journal June 2000
Effects of Surface Processing on the Response of CZT Gamma Detectors: Studies with a Collimated Synchrotron X-Ray Beam journal March 2008
Novel Approach to Surface Processing for Improving the Efficiency of CdZnTe Detectors journal August 2013
Topographic Evaluation of the Effect of Passivation in Improving the Performance of CdZnTe Detectors journal May 2014
New developments in CdTe and CdZnTe detectors for X and γ-ray applications journal June 1997
CdTe and CdZnTe detectors in nuclear medicine journal July 2000
Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
  • Verger, L.; Boitel, M.; Gentet, M. C.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 458, Issue 1-2 https://doi.org/10.1016/S0168-9002(00)00874-3
journal February 2001
New trends in CdTe and CdZnTe detectors for X- and gamma-ray applications journal May 2003
Performance of CdZnTe detectors passivated with energetic oxygen atoms
  • Prettyman, T. H.; Hoffbauer, M. A.; Rennie, J. A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 422, Issue 1-3 https://doi.org/10.1016/S0168-9002(98)00951-6
journal February 1999
Cadmium zinc telluride and its use as a nuclear radiation detector material journal April 2001
The surface leakage currents of CdZnTe wafers journal January 2007
Effect of surface preparation technique on the radiation detector performance of CdZnTe journal February 2008
Effect of surface treatments on the electrical and optical properties of CdZnTe single crystal
  • Zha, Gangqiang; Jie, Wanqi; Tan, Tingting
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 566, Issue 2 https://doi.org/10.1016/j.nima.2006.06.033
journal October 2006
Chemical treatment of CdZnTe radiation detectors using hydrogen bromide and ammonium-based solutions conference September 2014
Performance of an improved readout IC for multi-energy photon-counting x-ray detector arrays conference August 2008
Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications journal May 2009

Cited By (1)

Ammonium Fluoride Passivation of CdZnTeSe Sensors for Applications in Nuclear Detection and Medical Imaging journal July 2019

Similar Records

Analysis of Te and TeO2 on CdZnTe Nuclear Detectors Treated with Hydrogen Bromide and Ammonium-Based Solutions
Journal Article · Sat Apr 29 20:00:00 EDT 2017 · Journal of Materials Science and Chemical Engineering · OSTI ID:1376091

Study of Chemical Etching and Chemo-Mechanical Polishing on CdZnTe Nuclear Detectors
Journal Article · Mon Aug 12 20:00:00 EDT 2019 · Journal of Materials Science and Chemical Engineering · OSTI ID:1546037

Morphology, structure, and mechanical properties of the surface of PbTe crystals after etching with H{sub 2}O{sub 2}–HBr–ethylene glycol solutions
Journal Article · Thu Dec 14 23:00:00 EST 2017 · Inorganic Materials · OSTI ID:22788340