skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Best Estimate Radiation Flux Value-Added Procedure. Algorithm Operational Details and Explanations

Technical Report ·
DOI:https://doi.org/10.2172/1238060· OSTI ID:1238060
 [1];  [1]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States); DOE ARM Climate Research Facility, Washington, DC (United States)

This document describes some specifics of the algorithm for best estimate evaluation of radiation fluxes at Southern Great Plains (SGP) Central Facility (CF). It uses the data available from the three co-located surface radiometer platforms at the SGP CF to automatically determine the best estimate of the irradiance measurements available. The Best Estimate Flux (BEFlux) value-added procedure (VAP) was previously named Best Estimate ShortWave (BESW) VAP, which included all of the broadband and spectral shortwave (SW) measurements for the SGP CF. In BESW, multiple measurements of the same quantities were handled simply by designating one as the primary measurement and using all others to merely fill in any gaps. Thus, this “BESW” is better termed “most continuous,” since no additional quality assessment was applied. We modified the algorithm in BESW to use the average of the closest two measurements as the best estimate when possible, if these measurements pass all quality assessment criteria. Furthermore, we included longwave (LW) fields in the best estimate evaluation to include all major components of the surface radiative energy budget, and renamed the VAP to Best Estimate Flux (BEFLUX1LONG).

Research Organization:
DOE ARM Climate Research Facility, Washington, DC (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Biological and Environmental Research (BER)
DOE Contract Number:
AC05-7601830
OSTI ID:
1238060
Report Number(s):
DOE/SC-ARM/TR-008
Country of Publication:
United States
Language:
English