Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

Conference ·
OSTI ID:1238010
 [1];  [1];  [2]
  1. Malaviya National Institute of Technology (MNIT), Jaipur, India
  2. ORNL

The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
EE USDOE - Office of Energy Efficiency and Renewable Energy (EE)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1238010
Country of Publication:
United States
Language:
English

Similar Records

Performance evaluation of radiant cooling system integrated with air system under different operational strategies
Journal Article · Thu Mar 26 00:00:00 EDT 2015 · Energy and Buildings · OSTI ID:1185702

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions
Conference · Wed Feb 28 23:00:00 EST 2018 · OSTI ID:1456822

Performance assessment of radiant cooling system integrated with desiccant assisted DOAS with solar regeneration
Journal Article · Tue Jun 13 00:00:00 EDT 2017 · Applied Thermal Engineering · OSTI ID:1376508