skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

Journal Article · · Physical Review Special Topics - Accelerators and Beams

The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2/3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Lastly, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
Grant/Contract Number:
KE1870/DG/CLIC; AC02-07CH11359
OSTI ID:
1226657
Alternate ID(s):
OSTI ID: 1235050
Report Number(s):
FERMILAB-PUB-15-522-TD; PRABFM; 112802
Journal Information:
Physical Review Special Topics - Accelerators and Beams, Vol. 18, Issue 11; ISSN 1098-4402
Publisher:
American Physical SocietyCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 3 works
Citation information provided by
Web of Science

Similar Records

Submicron multi-bunch BPM for CLIC
Conference · Sun Aug 01 00:00:00 EDT 2010 · OSTI ID:1226657

EXPERIMENTAL RESULTS FROM A MICROWAVE CAVITY BEAM POSITION MONITOR.
Conference · Mon Mar 29 00:00:00 EST 1999 · OSTI ID:1226657

Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser
Journal Article · Thu Jan 15 00:00:00 EST 2015 · Review of Scientific Instruments · OSTI ID:1226657

Related Subjects