Building America Case Study: Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate, Ithaca, New York
"9One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests that observed temperature, humidity, and pressure conditions through the home and crawlspace. Additionally, CARB worked with NREL to perform multi-point tracer gas testing on six separate ventilation strategies - varying portions of 62.2 required flow supplied by the crawlspace fan and an upstairs bathroom fan. The intent of the tracer gas testing was to identify effective Reciprocal Age of Air (RAoA), which is equivalent to the air change rate in well-mixed zones, for each strategy while characterizing localized infiltration rates in several areas of the home.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1226487
- Report Number(s):
- NREL/FS-5500-64459; DOE/GO-102015-4700
- Country of Publication:
- United States
- Language:
- English
Similar Records
Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate
Technology Solutions Case Study: Sealed Crawl Space with Integrated Whole-House Ventilation in a Cold Climate
Related Subjects
Crawlspace
Ventilation
Whole-house ventilation
Exhaust-only ventilation
Radon
Code compliance
IRC
International Residential Code: ASHRAE 62.2
ASHRAE 62.2-2010
ASHRAE 62.2-2013
Tracer gas
SF6
Reciprocal Age of Air
RAoA
CARB
Consortium for Advanced Residential Buildings
SWA
Steven Winter Associates
Condensation potential
Dewpoint
Sealed crawlspace
Unvented crawlspace
Residentia