Unexpected Type of Failure of Thermal Battery Resulting in a Near Miss to a Serious Injury
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
On 6/26/2015 at 1445 in 894/136, a thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following a routine test where the battery is activated. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another containment box within the same room; initial indications are that the battery package ruptured after it went into thermal runaway which led to the operator receiving bruising to the palm of the hand from the pressure of the expulsion. The operator was wearing the prescribed PPE, which was safety glasses and a high temperature glove on the hand that was holding the battery.
- Research Organization:
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1225834
- Report Number(s):
- SAND2015--9119R; 607791
- Country of Publication:
- United States
- Language:
- English
Similar Records
In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402
Personal equipment for low seam coal miners: Development and testing of knit fabric gloves