Analyzing Design Heating Loads in Superinsulated Buildings

Technical Report ·
DOI:https://doi.org/10.2172/1215260· OSTI ID:1215260
 [1]
  1. Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

Research Organization:
National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
DOE Contract Number:
AC36-08GO28308
OSTI ID:
1215260
Report Number(s):
NREL/SR-5500-64236; MainId:18635; UUID:889011bd-0fed-e411-b3a2-d89d67132a6d; MainAdminID:7113
Country of Publication:
United States
Language:
English