Experimental Comparison of PV-Smoothing Controllers using Distributed Generators

Technical Report ·
DOI:https://doi.org/10.2172/1204101· OSTI ID:1204101
 [1];  [1];  [2];  [2];  [3];  [3];  [4];  [4];  [4]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
  2. Shimizu Corp., Tokyo (Japan)
  3. Public Service Company of New Mexico, Albuquerque, NM (United States)
  4. Tokyo Gas Co., New York, NY (United States)

The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA); USDOE Office of Energy Efficiency and Renewable Energy (EERE), Renewable Power Office. Solar Energy Technologies Office; USDOE Office of Electricity (OE)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1204101
Report Number(s):
SAND--2014-1546; 504878
Country of Publication:
United States
Language:
English

Similar Records

PV output smoothing using a battery and natural gas engine-generator.
Technical Report · Thu Jan 31 23:00:00 EST 2013 · OSTI ID:1093702

PV output smoothing with energy storage
Technical Report · Wed Feb 29 19:00:00 EST 2012 · OSTI ID:1039003

Performance assessment of the PNM Prosperity electricity storage project
Technical Report · Thu May 01 00:00:00 EDT 2014 · OSTI ID:1177058