Refinement of the Kansas City Plant site conceptual model with respect to dense non-aqueous phase liquids (DNAPL)

Technical Report ·
DOI:https://doi.org/10.2172/117791· OSTI ID:117791
;  [1];  [2]
  1. Oak Ridge National Lab., TN (United States)
  2. AlliedSignal Corp., Kansas City, MO (United States). Dept. of Environmental Protection

This document presents a refinement of the site conceptual model with respect to dense non-aqueous phase liquid (DNAPL) at the US Department of Energy Kansas City Plant (KCP). This refinement was prompted by a review of the literature and the results of a limited study that was conducted to evaluate whether pools of DNAPL were present in contaminated locations at the KCP. The field study relied on the micropurge method of sample collection. This method has been demonstrated as a successful approach for obtaining discrete samples within a limited aquifer zone. Samples were collected at five locations across 5-ft well screens located at the base of the alluvial aquifer at the KCP. The hypothesis was that if pools of DNAPL were present, the dissolved concentration would increase with depth. Four wells with highly contaminated groundwater were selected for the test. Three of the wells were located in areas where DNAPL was suspected, and one where no DNAPL was believed to be present. The results demonstrated no discernible pattern with depth for the four wells tested. A review of the data in light of the available technical literature suggests that the fine-grained nature of the aquifer materials precludes the formation of pools. Instead, DNAPL is trapped as discontinuous ganglia that are probably widespread throughout the aquifer. The discontinuous nature of the DNAPL distribution prevents the collection of groundwater samples with concentrations approaching saturation. Furthermore, the results indicate that attempts to remediate the aquifer with conventional approaches will not result in restoration to pristine conditions because the tortuous groundwater flow paths will inhibit the efficiency of fluid-flow-based treatments.

Research Organization:
Oak Ridge National Lab., TN (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
117791
Report Number(s):
ORNL/TM--13003; ON: DE96000846
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of micropurging versus traditional groundwater sampling at the Department of Energy`s Kansas City Plant
Conference · Tue Aug 01 00:00:00 EDT 1995 · OSTI ID:104990

Spatial and temporal dynamics of organohalide-respiring bacteria in a heterogeneous PCE–DNAPL source zone
Journal Article · Sat Aug 22 00:00:00 EDT 2015 · Journal of Contaminant Hydrology · OSTI ID:1471950

DNAPL flow behavior in a contaminated aquifer: Evaluation of field data
Journal Article · Sat Dec 30 23:00:00 EST 1995 · Ground Water Monitoring and Remediation · OSTI ID:153502