Indoor air quality in 24 California residences designed as high-performance homes

Journal Article · · Science and Technology for the Built Environment
 [1];  [2];  [1];  [1]
  1. Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)
  2. Gap, Inc., San Francisco, CA (United States)
Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH50, n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr-1, n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.
Research Organization:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC); USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
DOE Contract Number:
AC02-05CH11231
OSTI ID:
1171350
Report Number(s):
LBNL--6937E
Journal Information:
Science and Technology for the Built Environment, Journal Name: Science and Technology for the Built Environment Journal Issue: 1 Vol. 21; ISSN 2374-4731
Publisher:
Taylor and Francis
Country of Publication:
United States
Language:
English

Similar Records

Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits
Technical Report · Sun Jun 01 00:00:00 EDT 2014 · OSTI ID:1167382

Assessing Occupant and Outdoor Air Impacts on Indoor Air Quality in New California Homes
Conference · Fri Sep 01 00:00:00 EDT 2017 · OSTI ID:1506279

Indoor Air Quality in 24 California Residences Designed as High-Performance Homes
Technical Report · Wed Jul 01 00:00:00 EDT 2015 · OSTI ID:1220528