Title: Drop tests of the redesigned 9975 package June 2000

Technical Report ·
DOI:https://doi.org/10.2172/1169583· OSTI ID:1169583
 [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

A redesigned closure for the 9975, based on that employed on the DT-22 family of packages, has been developed. The tests reported here qualify the redesigned package with respect to the requirements of 10 CFR 71. ln order to ensure that the vessel and its closure were tested in the most challenging condition, each of the packages was subjected to a Normal Conditions of Transport (NCT) preconditioning test followed by the Hypothetical Accident Condition (HAC) 30 ft drop and puncture pin tests. The tests demonstrated the ability of the 9975 with the redesigned closure to withstand the RAC drop test sequence.