Design and Error Analysis of the Quadrupole Pick-Up Coils for use with the Booster Gauss Clock
- Brookhaven National Laboratory (BNL), Upton, NY (United States)
Pickup coils for use with the booster quadrupole Gauss clocks have been designed and a detailed error analysis done. The coils of the basic Gauss clock unit will be mounted in the two booster quadrupole reference magnets No. QH25 and QV25 located in building 930A. The coils will provide a voltage which is proportional to B. The number of coil windings and form dimensions have been chosen to produce 1 volt/1Tesla/sec. This report is divided into three parts. Part I describes the design and documents the calculation done to determine the form dimensions and the number of windings. In Part II a general formalism is developed for calculating errors and Part III looks at four types of possible errors; due to (1) Lateral motion of the coils (left-right), (2) the effect of a non-zero B3 term (sextupole term), (3) Errors due to rotation of the coils, and (4) errors due to differences in the coil width.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 1150571
- Report Number(s):
- BNL--105237-2014-IR
- Country of Publication:
- United States
- Language:
- English
Similar Records
Absolute Calibration of the Booster Gauss Clock
Backup of the Booster Gauss Clock
Gauss Clock, Gauss Line and Magnet Integration
Technical Report
·
Thu Nov 29 23:00:00 EST 1990
·
OSTI ID:1150564
Backup of the Booster Gauss Clock
Technical Report
·
Wed Jul 22 00:00:00 EDT 1992
·
OSTI ID:1150588
Gauss Clock, Gauss Line and Magnet Integration
Technical Report
·
Thu Jul 30 00:00:00 EDT 1992
·
OSTI ID:1150590