Anatomic standardization: Linear scaling and nonlinear warping of functional brain images

Journal Article · · Journal of Nuclear Medicine
OSTI ID:114868
; ;  [1]
  1. Univ. of Michigan, Ann Arbor, MI (United States); and others

An automated method was proposed for anatomic standardization of PET scans in three dimensions, which enabled objective intersubject and cross-group comparisons of functional brain images. The method involved linear scaling to correct for individual brain size and nonlinear warping to minimize regional anatomic variations among subjects. In the linear-scaling step, the anteroposterior length and width of the brain were measured on the PET images, and the brain height was estimated by a contour-matching procedure using the midsagittal plane. In the nonlinear warping step, individual gray matter locations were matched with those of a standard brain by maximizing correlation coefficients of regional profile curves determined between predefined stretching centers (predominantly in white matter) and the gray matter landmarks. The accuracy of the brain height estimation was compared with skull x-ray estimations, showing comparable accuracy and better reproducibility. Linear-scaling and nonlinear warping methods were validated using ({sup 18}F)fluorodeoxyglucose and ({sup 15}O)water images. Regional anatomic variability on the glucose images was reduced markedly. The statistical significance of activation foci in paired water images was improved in both vibratory and visual activation paradigms. A group versus group comparison following the proposed anatomic standardization revealed highly significant glucose metabolic alterations in the brains of patients with Alzheimer`s disease compared with those of a normal control group. These results suggested that the method is well suited to both research and clinical settings and can facilitate pixel-by-pixel comparisons of PET images. 26 refs., 9 figs., 1 tab.

DOE Contract Number:
FG02-87ER60561
OSTI ID:
114868
Journal Information:
Journal of Nuclear Medicine, Journal Name: Journal of Nuclear Medicine Journal Issue: 9 Vol. 35; ISSN 0161-5505; ISSN JNMEAQ
Country of Publication:
United States
Language:
English

Similar Records

Inter-subject MR-PET image registration and integration
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513319

A general technique for interstudy registration of multifunction and multimodality images
Conference · Wed Nov 30 23:00:00 EST 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6706290

Evaluation of MRI and cannabinoid type 1 receptor PET templates constructed using DARTEL for spatial normalization of rat brains
Journal Article · Mon Dec 14 23:00:00 EST 2015 · Medical Physics · OSTI ID:22482423