Title: Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU

Conference · · AIP Conf. Proc.
DOI:https://doi.org/10.1063/1.4860718· OSTI ID:1132612

The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system.

Research Organization:
Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC05-06OR23177
OSTI ID:
1132612
Report Number(s):
JLAB-ACE-13-1788; DOE/OR/23177-3075
Journal Information:
AIP Conf. Proc., Vol. 1573; Conference: ADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference - CEC, 17–21 June 2013, Anchorage, Alaska
Country of Publication:
United States
Language:
English

Similar Records

Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU
Journal Article · Wed Jan 29 00:00:00 EST 2014 · AIP Conference Proceedings · OSTI ID:1132612

Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade
Conference · Tue Dec 01 00:00:00 EST 2015 · IoP Conf.Ser.Mat.Sci.Eng. (Advances in Cryogenic Engineering: CEC 2015) · OSTI ID:1132612

The Hall D solenoid helium refrigeration system at JLab
Conference · Wed Jan 01 00:00:00 EST 2014 · AIP Conf. Proc. · OSTI ID:1132612