Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU
- JLAB
- Michigan State University
The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system.
- Research Organization:
- Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC05-06OR23177
- OSTI ID:
- 1132612
- Report Number(s):
- JLAB-ACE-13-1788; DOE/OR/23177-3075
- Conference Information:
- Journal Name: AIP Conf. Proc. Journal Volume: 1573
- Country of Publication:
- United States
- Language:
- English
Similar Records
Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU
Conceptual design of the FRIB cryogenic system
The Hall D solenoid helium refrigeration system at JLab
Journal Article
·
Tue Jan 28 23:00:00 EST 2014
· AIP Conference Proceedings
·
OSTI ID:22263942
Conceptual design of the FRIB cryogenic system
Conference
·
Fri Jun 01 00:00:00 EDT 2012
· AIP Conf. Proc.
·
OSTI ID:1046953
The Hall D solenoid helium refrigeration system at JLab
Conference
·
Tue Dec 31 23:00:00 EST 2013
· AIP Conf. Proc.
·
OSTI ID:1132614