Air sparging and soil vapor extraction to remediate ground water
- ATEC Associates, Inc., Raleigh, NC (United States)
An Air Sparging and Soil Vapor Extraction System was chosen to remediate petroleum impacted ground water over traditional remedial alternatives, such as ``pump and treat``, to expedite site closure. Field pilot testing, computer modeling and cost benefit analyses performed for several alternatives. Air Sparging and Soil Vapor Extraction pilot studies proved this technology to be the most effective with respect to remedial and economic concerns. Underground Storage Tanks (USTs) were closed at the facility located in North Eastern North Carolina in August of 1992. During UST closure, petroleum impacted ground water and soils were encountered. ATEC performed a Comprehensive Site assessment to delineate the impacted soil and ground water plume. Following completion of the site assessment, a Corrective Action Plan was prepared. As part of the Corrective Action Plan preparation, field pilot testing was performed to evaluate remedial alternatives and provide information for full scale design. The full scale treatment system was installed and started in January 1994. This effective Remedial System was selected over other options due to successful pilot testing results with site closure petitioning scheduled within 12 to 14 months after start up. The Air Sparging System, properly applied, is an effective and ``quick`` remedial option with no generation of ground water for disposal and permitting. This paper concentrates on the Air Sparging application applied at this North Carolina site. Although Vapor extraction was also implemented, this presentation does not elaborate on vapor extraction design or implementation and only discusses vapor extraction where it is directly related to the Air Sparging System.
- OSTI ID:
- 113200
- Report Number(s):
- CONF-940499--; ISBN 1-56590-014-6
- Country of Publication:
- United States
- Language:
- English
Similar Records
In-situ air sparging under confined aquifer conditions
In-situ bioventing and air sparging for remediation of LUST sites