Characterization of Specimens Exposed in a Li Loop
Conference
·
OSTI ID:1130824
- ORNL
A monometallic V-4Cr-4Ti thermal convection loop was run for 2,350 h with a peak temperature of 700 C and Li flow rate of 2-3 cm/s. Specimens of V-4Cr-4Ti exposed in the hot and cold leg were tensile tested in vacuum at 500 C showing an increase in the 0.2% yield and ultimate tensile strengths and a decrease in the serration amplitude with decreasing exposure temperature in the loop. However, only minor changes in ductility were measured. With the higher temperature exposures, there was a decrease in Vickers hardness measured but little change in the grain size. Characterization of the microstructure after exposure at 627 C in the loop showed an increase in the density of Ti- and N-rich grain boundary and matrix precipitates near the specimen surface after exposure corresponding to an increase in the hardness in the near-surface region. Two-layer V/Y2O3 coatings on V-4Cr-4Ti substrates also were exposed in the loop and initial room temperature characterization has been conducted.
- Research Organization:
- Oak Ridge National Laboratory (ORNL); Center for Nanophase Materials Sciences (CNMS)
- Sponsoring Organization:
- SC USDOE - Office of Science (SC)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1130824
- Country of Publication:
- United States
- Language:
- English
Similar Records
Compatibility of V/Y2O3/V-4Cr-4Ti Coatings with Liquid Flowing Li
Initial Characterization of V-4Cr-4Ti and MHD Coatings Exposed to Flowing Li
Performance of V-4Cr-4Ti material exposed to DIII-D tokamak environment
Conference
·
Sat Dec 31 23:00:00 EST 2011
·
OSTI ID:1049816
Initial Characterization of V-4Cr-4Ti and MHD Coatings Exposed to Flowing Li
Conference
·
Wed Dec 31 23:00:00 EST 2008
·
OSTI ID:951919
Performance of V-4Cr-4Ti material exposed to DIII-D tokamak environment
Technical Report
·
Mon Mar 31 23:00:00 EST 1997
·
OSTI ID:543266